4AFC

University of Canterbury Four-Alternative Forced Choice Speech Test




Results

Calibration

Turn device volume fully up and leave it there. Choose your method, play the 1 kHz tone (or, for sound field, the calibration noise), set the level by your chosen method, then stop and enter the value(s). That becomes the reference; presentation level is set with the slider below.



    Setup

    Mode

    Adapts the equivalent low-pass cutoff (Hz).

    Procedure
    Common
    Filter

    The presentation level is set on the front page.

    WUDR (two-phase)

    Defaults: down −4.76% / up +8.33% (working); down −11.1% / up +20.8% (initial). 0 reversals = single-phase.

    Presentation routing

    Applies to the stimuli for this run.

    Normative data

    Collect normalisation data using the method of constant stimuli (fixed list of SNRs or LPF cutoffs, every word at every level, repeated).

    Constant Stimuli

    Mode

    SNR and LPF each keep their own saved level list.

    Ear

    Which ear(s) the stimuli and noise are routed to.

    Levels

    After shuffling, the first N presentations are reordered easiest→hardest to ease the participant in, then the rest play shuffled. 0 = fully shuffled.

    Verify low-pass filter

    Frequency response of the exact filter applied to the stimuli (10th-order Butterworth, built at 48 kHz — the sound-file rate). The smooth line is the analytic response of the filter coefficients; the dots are measured by passing white noise through the identical filter code and averaging. Unfiltered = 0 dB; the dashed marker shows the −3 dB point at the corner frequency.


    Thank you for participating!